0.6/1kV CU/XLPE/PVC Cable

 


0.6/1kV CU/XLPE/PVC Cable Introduction

Conductors

Copper conductor

Insulation

XLPE (Cross-Linked Polyethylene)

Outer Sheath

PVC (Polyvinyl Chloride)

Application

These cables are used for electricity supply in low voltage installation system. They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Product Parameters

  • Single core(unarmoured)

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

1x1.5

1.4

0.7

1.4

5.6

1x2.5

1.8

0.7

1.4

6

1x4

2.3

0.7

1.4

6.5

1x6

2.8

0.7

1.4

7

1x10

3.6

0.7

1.4

7.8

1x16

4.5

0.7

1.4

8.7

1x25

5.6

0.9

1.4

10.2

1x35

6.7

0.9

1.4

11.3

1x50

8

1

1.4

12.8

1x70

9.4

1.1

1.4

14.4

1x95

11

1.1

1.5

16.1

1x120

12.4

1.2

1.5

17.8

1x150

13.8

1.4

1.6

19.8

1x185

15.3

1.6

1.6

21.8

1x240

17.5

1.7

1.7

24.4

1x300

19.5

1.8

1.8

26.7

1x400

22.6

2

1.9

30.5

1x500

25.2

2.2

2

33.7

1x630

28.3

2.4

2.2

37.4

 

  • Two cores(unarmoured)

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

2x1.5

1.4

0.7

1.8

9.2

2x2.5

1.8

0.7

1.8

10

2x4

2.3

0.7

1.8

11

2x6

2.8

0.7

1.8

12

2x10

3.6

0.7

1.8

13.6

2x16

4.5

0.7

1.8

15.4

2x25

5.6

0.9

1.8

18.4

2x35

6.7

0.9

1.8

20.6

2x50

8

1

1.8

23.6

2x70

9.4

1.1

1.8

26.8

2x95

11

1.1

1.9

30.2

2x120

12.4

1.2

2

33.7

2x150

13.8

1.4

2.2

37.5

2x185

15.3

1.6

2.3

41.6

2x240

17.5

1.7

2.5

46.7

2x300

19.5

1.8

2.6

51.4

2x400

22.6

2

2.9

58.9

 

  • Three cores(unarmoured)

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

3x1.5

1.4

0.7

1.8

9.6

3x2.5

1.8

0.7

1.8

10.5

3x4

2.3

0.7

1.8

11.6

3x6

2.8

0.7

1.8

12.6

3x10

3.6

0.7

1.8

14.4

3x16

4.5

0.7

1.8

16.3

3x25

5.6

0.9

1.8

19.5

3x35

6.7

0.9

1.8

21.9

3x50

8

1

1.8

25.1

3x70

9.4

1.1

1.9

28.7

3x95

11

1.1

2

32.4

3x120

12.4

1.2

2.1

36.1

3x150

13.8

1.4

2.3

40.3

3x185

15.3

1.6

2.4

44.6

3x240

17.5

1.7

2.6

50.2

3x300

19.5

1.8

2.7

55.2

3x400

22.6

2

3

63.3

 

  • 3+1 Cores(unarmoured)

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

mm

mm

3x 16/10

4.5

3.6

0.7

0.7

1.8

17.5

3x 25/16

5.6

4.5

0.9

0.7

1.8

21.2

3x 35/16

6.7

4.5

0.9

0.7

1.8

23.8

3x 50/25

8

5.6

1

0.9

1.8

27.5

3x 70/35

9.4

6.7

1.1

0.9

2

31.7

3x 95/50

11

8

1.1

1

2.1

35.8

3x120/70

12.4

9.4

1.2

1.1

2.3

39.9

3x150/70

13.8

9.4

1.4

1.1

2.4

44.6

3x185/95

15.3

11

1.6

1.1

2.6

49.5

3x240/120

17.5

12.4

1.7

1.2

2.8

55.7

3x300/150

19.5

13.8

1.8

1.4

3

61.4

3x400/185

22.6

15.3

2

1.6

3.2

70.4

 

  • Four cores(unarmoured)

Nominal Cross Section

Diameter of Conductor (Approx.)

Nominal Insulation Thickness

Nominal Sheath Thickness

Overall Diameter (Approx.)

mm²

mm

mm

mm

mm

4x1.5

1.4

0.7

1.8

10.4

4x2.5

1.8

0.7

1.8

11.3

4x4

2.3

0.7

1.8

12.5

4x6

2.8

0.7

1.8

13.7

4x10

3.6

0.7

1.8

15.7

4x16

4.5

0.7

1.8

17.8

4x25

5.6

0.9

1.8

21.5

4x35

6.7

0.9

1.8

24.1

4x50

8

1

1.8

27.8

4x70

9.4

1.1

2

32

4x95

11

1.1

2.1

36.1

4x120

12.4

1.2

2.3

40.2

4x150

13.8

1.4

2.4

44.9

4x185

15.3

1.6

2.6

49.8

4x240

17.5

1.7

2.8

56

4x300

19.5

1.8

3

61.7

4x400

22.6

2

3.2

70.7

 

Comments

Popular posts from this blog

Understanding Voltage Levels and Cable Types in China's Power Industry

Comparison of Flame Retardant Standards for Electric Wires and Cables

What Are Trailing Cables and Where Are They Used?

Understanding Low Voltage Power Cables: A Comprehensive Guide

Medium Voltage Cable Life Expectancy: Factors and Insights

4 AWG Wire: Definition, Specifications, Ampacity, and MM² Equivalent

Optimized Design of Smooth Aluminum Sheath Thickness for High-Voltage Cables Using the Short-Circuit Capacity Method

Residential Wiring: Types, Gauges, Wires, and Standards

Single-Core Wires: Applications and Functionality

All Cable Products-Henan Province Jianyun Cable Co., Ltd.