Al Overhead ABC Cable (Sizes 16 to 70mm²)

Key attributes

Industry-specific attributes

Insulation Material

/

Application

Construction

Conductor Material

Aluminum

Jacket

/

Other attributes

Place of Origin

Henan, China

Working Temperature

90°C, 70°C

Rated Voltage

1 kV

Rated Current

16A, 30A

Brand Name

JYXL

Model Number

Aerial Bundled Cables to NFC 33-209

Type

LOW VOLTAGE

Product name

16mm2 25mm2 50mm2 70mm2 Aluminium Conductors Overhead ABC Cable 70mm2

Conductor

Aluminum

Color

Black

Insulation

xlpe

Certificate

IEC

Rated voltage

0.6/1KV

MOQ

1000

Standard

NFC 33-209

Package

Wooden Drum

Usage

Power Transmission Lines

PRODUCT SHOW

16mm2 25mm2 50mm2 70mm2 Aluminium Conductors Overhead ABC Cable 70mm2  

Construction

Phase Conductor:Aluminium conductor, round stranded compressed (RM).

Neutral Conductor:Alloy aluminium conductor , round stranded compressed (RM).

Insulation:XLPE

Standard

NFC 33-209

Application

The aerial bundled cables designed for fixed installation as overhead power lines up to 1000 V incl.

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

PRODUCT DETAIL

Number of cores x nominal cross section

max. conductor- resistance

min. breaking load of conductor strand

Current rating in the air

Outer diameter

Total weight

mm²

Ohm/km

kN

A

mm

kg/km

2x10 RM

3.08

1.5

38

12.8

93

4x10 RM

3.08

1.5

38

15.4

183

2x16 RM

1.91

2.3

72

14.8

129

2x16 RN + 2x1.5 RE

1.910/12.100

2.3

72

14.8

176

4x16 RM

1.91

2.3

72

17.8

257

4x16 RN + 2x1.5 RE

1.910/12.100

2.3

72

17.8

304

2x25 RM

1.2

3.8

107

18

202

2x25 RM + 2x1,5 RE

1.200/12.100

3.8

107

18

249

4x25 RM

1.2

3.8

107

21.7

404

4x25 RM + 2x1,5 RE

1.200/12.100

3.8

107

21.7

451

2x35 RM

0.868

5.2

132

20.8

269

2x35 RM + 2x1,5 RE

0.868/12.100

5.2

132

20.8

316

4x35 RM

0.868

5.2

132

25.1

539

4x35 RM + 2x1,5 RE

0.868/12.100

5.2

132

25.1

586

2x50 RM

0.641

7.6

165

23.4

352

2x50 RM + 2x1,5 RE

0.641/12.100

7.6

165

23.4

399

1x54.6 RM + 3x25 RM

0.630/1.200

3.8

107

21.7

507

1x54.6 RM + 3x25 RM + 1x16 RM

0.630/1.200/1.910

3.8/2.3

107/72

24.3

573

1x54.6 RM + 3x25 RM + 2x16 RM

0.630/1.200/1.910

3.8/2.3

107/72

29.7

639

1x54.6 RM + 3x25 RM + 3x16 RM

0.630/1.200/1.910

3.8/2.3

107/72

31.1

705

1x54.6 RM + 3x35 RM

0.630/0.868

5.2

132

25.1

615

1x54.6 RM + 3x35 RM + 1x16 RM

0.630/0.868/1.910

5.2/2.3

132/72

28.1

680

1x54.6 RM + 3x35 RM + 2x16 RM

0.630/0.868/1.910

5.2/2.3

132/72

34.3

748

1x54.6 RM + 3x35 RM + 3x16 RM

0.630/0.868/1.910

5.2/2.3

132/72

35.9

814

1x54.6 RM + 3x35 RM + 1x25 RM

0.630/0.868/1.200

5.2/3.8

132/107

28.1

714

1x54.6 RM + 3x50 RM

0.630/0.641

7.6

165

28.2

741

1x54.6 RM + 3x50 RM + 1x16 RM

0.630/0.641/1.910

7.6/2.3

165/72

31.6

806

1x54.6 RM + 3x50 RM + 2x16 RM

0.630/0.641/1.910

7.6/2.3

165/72

38.6

875

1x54.6 RM + 3x50 RM + 3x16 RM

0.630/0.641/1.910

7.6/2.3

165/72

40.4

940

1x54.6 RM + 3x50 RM + 1x25 RM

0.630/0.641/1.200

7.6/3.8

165/107

31.6

841

1x54.6 RM + 3x70 RM

0.630/0.443

10.2

205

33

950

1x54.6 RM + 3x70 RM + 1x16 RM

0.630/0.443/1.910

10.2/2.3

205/72

37

1014

1x54.6 RM + 3x70 RM + 2x16 RM

0.630/0.443/1.910

10.2/2.3

205/72

45.2

1083

1x54.6 RM + 3x70 RM + 3x16 RM

0.630/0.443/1.910

10.2/2.3

205/72

47.3

1148

1x54.6 RM + 3x70 RM + 1x25 RM

0.630/0.443/1.200

10.2/3.8

205/107

37

1048

1x54.6 RM + 3x70 RM + 2x25 RM

0.630/0.443/1.200

10.2/3.8

205/107

45.2

1150

1x54.6 RM + 3x70 RM + 3x25 RM

0.630/0.443/1.200

10.2/3.8

205/107

47.3

1250

1x54.6 RM + 3x95 RM

0.630/0.320

13.5

240

37.4

1176

1x54.6 RM + 3x95 RM + 1x16 RM

0.630/0.320/1.910

13.5/2.3

240/72

41.9

1243

 


Comments

Popular posts from this blog

How to Distinguish High Voltage Wires from Low Voltage Wires

Electrical Cable Standards in France

Can I Use a 110V Rated Wire for 12V Applications?

What is the Difference Between Low Voltage Wire and Regular Wire?

What Are the Applications of Electrical Cables? A Comprehensive Guide

What is the Function of an Electrical Wire? A Comprehensive Guide

Difference Between C7 and C8 Power Cables

What Are Trailing Cables and Where Are They Used?

Cross-Sectional Area of Wire: How to Calculate and Select Properly?

Understanding BV, BVR, and RV Cables

All Cable Products-Henan Province Jianyun Cable Co., Ltd.